Installation
20
Operating manual INVEOR
ATTENTION!
Risk of damaging the drive control.
The correct phase sequence must be observed when the drive control is
connected, as the motor could otherwise be overloaded.
Ensure that the phase sequence is correct when connecting the motor.
The supplied assembly material can be used to connect core end sleeves
and cable shoes. Fig. 4 shows the different connection options.
Unused open cable ends in the motor terminal box must
be insulated.
If a PTC or Klixxon is used, the electric jumper fitted on
the connection terminal for the PTC in the delivery state
has to be removed.
The cross-section of the supply line has to be designed according to the
transfer category and the maximum permitted current. The contractor starting
up the device must ensure the power line protection.
3.2.4
Short circuit and ground protection
The drive control contains an internal short circuit and ground protection.