![Kostal INVEOR MA Operating Manual Download Page 38](http://html1.mh-extra.com/html/kostal/inveor-ma/inveor-ma_operating-manual_1999368038.webp)
Commissioning
38
Operating manual INVEOR
4.3
Block diagram
Analogue input 1
Motorized potentiometer
HMI / PC
Internal potentiometer
Analogue input 2
Reference
channel
1.130
Analogue input 1
Analogue input 2
PID feedback
3.060
Digital input 2
Autostart
Fieldbus
Digital input 3
Enable software
1.131
Digital input 1
Control
mode
1.100
Frequency
control mode
PID process
control
Motor
control
Total AI1 / AI2
Digital input 4
Preset speed
mode
X(-1)
1.150
Revers Speed
direction
Low-/ High-
speed
1.020 1.021
f
t
Ramps
1.051 1.050
f
t
1.053 1.052
Analogue input 1
Analogue input 2
Control modes
PID present reference
Motor current limit
I
t
5.070 5.071
Fieldbus
Reference
speed
Fig. 17: General structure of target value generation