a) Data identification code
b) N coordinate
c) E coordinate
d) Z coordinate
e) Point number
9
)
Property code input command ( /Dh)
/Dh ABC.DEF, …, XYZ[,SUM]CRLF
a b
a)
Data identification code
b)
It is possible to enter 40 pieces of property codes which contains 14 characters length into instrument
memory.
1.3 Set Command
After computer sending input command to instrument, a receiving state code will be send from instrument to
computer. (ACK/NAK communication control)
1.
06H
(
ACK
)
:
data communicating succeeded, send next command
2.
15H
(
NAK
)
:
data communicating failed, resend command
Note
:
Please refer to “sending commend and outputting data” section
.
·
Set command format
Following commands end with CRLF(0DH,0AH) or CR(0DH).
1.
Xa: Set distance measurement mode to be fine single measurement.
2.
Xb: Set distance measurement mode to be fine repeat measurement.
3.
Xc: Set distance measurement mode to be fine N-times measurement.
4. Xe: Set distance measurement mode to be tracking measurement.
5. Xh: Set the horizontal angle to 0
6. Xd: Set the last measured coordinate to occupied coordinate.
7. Xi: Set coordinate bearing angle base on the coordinates of occupied point and backsight point
8. Xk: Set the horizontal angle to right angle (HAR)
9. XL: Set the horizontal angle to left angle (HAL)
10. XO: Change the start point in MLM measurement
11. Xr: Screen backlight on
12. Xs: Screen backlight off
13. Xt: Clear all the coordinate data in memory.
14. Xs: Switch off screen illumination.
15. Xt: Clear all coordinates data in memory.