78
PROCEDURE
Operating Procedure
Operation
Display
⑴
Set the prism directly under or directly over
the object and measure the target height with a
tape measure.
Press HT on the third page of “MEAS Mode
Screen”. The “Height Setting Screen” is
displayed.
HT
Height
Tgt.h.
:
1.650 m
Inst. h.
:
2.000 m
OK
⑵
Enter the prism height and press OK, sight
the prism. Press SD on the first page of the
MEAS Mode to begin distance measurement.
(The Distance mode may be either SD, HD, or
VD).
OK
+
SD
Dist.
Dist PC = 0
PPM = 0
Fine “S”
STOP
⑶
When the observation is completed, the
distance measurement result is displayed.
Meas. PC -30
PPM 0
S 11.678 m
ZA 59°39′54″
HAR 90°01′00″
P2
SD SHV HSET EDM
⑷
Sight the target, display the screen in which
REM is registered. Press REM to begin the
REM measurement. 0.7 seconds later, the height
from the surveying point to the target is displayed
in HT. Afterwards, the measurement values are
completed every 0.5 seconds.
REM
REM
Ht. 0.052 m 3
S 13.123 m
ZA 89°23′54″
HAR 117°12′17″
STOP
⑸
Press STOP to end the REM measurement
operation.
·
Re-observe the target (distance measurement):
OBS (Afterwards returns to step 2.)
·
Start REM measurement: REM
STOP
REM
Ht. 0.052 m 3
S 13.123 m
ZA 89°23′54″
HAR 117°12′17″
REM OBS