80
·
It is possible to read in a coordinate data registered in advance.
·
It is possible to record set known point coordinate data or calculated instrument station data in the JOB which has
been selected. For the JOB selection method, see “16.1 JOB Selection”.
·
The target height set here returns to its previously set value after the resection process is completed.
PROCEDURE
Operating Procedure
Operation
Display
⑴
Press RESE in the third page of Meas.
Mode, or from page 2 of Menu Program.
Input coordinate values for the 1 st known point
and press F4 OK.
·
Stopping an entry in progress: ESC
·
Reading in data: READ
·
Record data: REC
Input
Coordinate
+
F4 OK
Resection
Pt. 1
N 0.000 m 3
E 0.000 m
Z 0.000 m
READ REC OK
Resection
Pt. 1
N 2705009.600 m 3
E 585500.964 m
Z 3.201 m
READ REC OK
⑵
When coordinate entry for the 1 st point
has been completed, press OK. The “2 nd
Point Setting Screen” is displayed.
·
Repeat step 1 to input the coordinates of all the
known point.
Input
coordinate
values
Resection
Pt. 2
N 2705618.561 m 3
E 585502.155 m
Z 3.254 m
MEAS READ REC OK
⑶
When all required known points have been
set,s press MEAS.
MEAS
Resection
N 2705009.600 m 3
E 585500.964 m
Z 3.201 m
Sight Pt. 1
ANG. DIST
⑷
Sight the 1 st known point, press ANG for
angle measurement only. Or press F4 DIST for
angle and distance measurement. When DIST is
selected, the “Observation Start Screen” is
displayed.
F4
DIST
Resection
Dist PC = 0
PPM = 0
Fine “S”
STOP