157
⑹
Press OBS to measure the coordinates again
in Record Mode.
OBS.
Coordinates
Coord. PC = 0
PPM = 0
Fine “S”
STOP
⑺
Press ESC to restore the “Record Mode
Screen.”
ESC
1. Stn data A:\JOB01
2. back sight data
3. angle data
4. dist data
5. Coord data
6. dist+ coord data
Perform distance measurement to record automatically by pressing a single key: AUTO.
When this key is used, it is unnecessary to perform distance measurement in MEAS Mode. Press AUTO on the
“Record Mode Screen” to perform distance measurement and automatically record the results. When this is done,
the point number automatically increases from that displayed when the KTS entered Record Mode and the code
that was displayed is used unchanged. After measurement has been completed, the results are display for 2 seconds
and the screen displayed before AUTO was pressed is restored.
·
Offset measurement in Record mode: OFFSET
It is possible to advance through “Offset/Dist” and “Offset/Angle” by pressing OFFSET. See “12. Offset
Measurement” for the procedure.
21.6 Recording distance and coordinate data.
The function can measure distance and coordinate at the same time then record distance data and coordinate data
seperately in working jobs.
·
Under record mode, distance measurement data and coordinate data can be saved in working jobs.
·
To avoid recording data repeatedly, after recording each measured data, before measuring new data, it will not
show the REC. function.
·
Following distance measurement data will be saved
:
vertical angle, horizontal angle,code, target height.
Following distance measurement data will be saved: N, E, Z coordinate value, point name, target height, code.
Operation Procedure
Key
Display
⑴
In REC. menu choose “6. Dist+ Coord. data”.
“6. Dist+
Coord data”
+
ENT
1. Stn data JOB01 ↑
2. Back sight data
3. Angle data
4. Dist data
5. Coord data
6. Dist+ coord data ↓