58
⑺
Set the prism on the sight-line and sight it.
Press HD to start distance setting-out
measurement.
·
Press SHV to select measurement mode.
HD
S-O
S-O PC = 0
PPM = 0
Fine “ S”
STOP
⑻
When the observation is completed. The
distance to the point to be set out is displayed on
line 2.The movement direction of the target is
indicated by the arrows pointing upwards and
downwards.
← → 0°00′00″
↑ 2.456 3
S 123.234 m
ZA 89°45′23″
HAR 150°16′54″
REC SHV <--> HD
⑼
Move the prism toward and backward until
distance on line 2 is 0 m, then press SHV select
SD, VD to perform the measurement.
When it is within a range of ±1cm, both arrows
are displayed. (If repeat measurement or
tracking measurement is performed at this time,
it is possible to display the measurement results
without any key operations while sighting the
target which was moved.)
↓: Move the prism towards your side.
↑: Move the prism away from your side.
SHV
← → 0°00′00″
↑ ↓ 0.000 3
S 12.234 m
ZA 89°45′23″
HAR 150°16′54″
REC SHV <--> HD
⑽
Find the place where the distance is 0 m.
← → 0°00′00″
↑ ↓ 0.000 3
S 12.234 m
ZA 89°45′23″
HAR 150°16′54″
REC SHV <--> HD
⑾
Press ESC to return to Setting-out
measurement menu screen.
ESC
S-O
1. Observation
2. S-O data
3. Stn data
4. Set h angle
5. EDM
·
To record the coordinate of measured point: REC