D.3.9 Clear IP configuration
Description
The command ‘.clear ip0;’ will revert the IP configuration parameters to defaults.
Argument (none)
Example
Request
.clear ip0;
Response
.ok
D.4 Serial interface configuration
Serial interface configuration command responses are sent before the configuration is changed. The actual change of configuration
happens a few seconds later, possibly while sending a status message.
D.4.1 Set serial interface baud rate
Description
The command: ‘.set ser0baudrate=<rate>;’ will set the baud rate.
Argument (1)
Description baud
rate
Type
integer
Range
4800, 9600, 19200, 38400, 57600, 115200
Default value
19200
Example
Request:
.set ser0baudrate=115200;
Response:
.ok;
D.4.2 Show serial interface baud rate
Description
The command: ‘.show ser0baudrate;’ will show the configured baud rate.
Argument (none)
Example
Request:
.show ser0baudrate;
Response:
.ser0baudrate=115200;
.ok;