2-10
Return to
Section Topics
2308-900-01 Rev. A / July 2008
Section 2: Basic Power Supply Operation
Model 2308 Portable Device Battery/Charger Simulator User’s Manual
To edit voltage and current values from the front panel:
1. Press
the
SET
key to select the output settings mode. A blinking cursor appears in the
voltage field of the display.
2. Press
the
▲
,
▼
, ,
or
keys to scroll to the desired output voltage value.
• The cursor position (blinking digit) is controlled by the
or
keys.
• With the cursor positioned on a digit, increment or decrement the value using the
▲
or
▼
keys.
3. Press
SET
to move the blinking cursor to the current limit field.
4. Press
the
▲
,
▼
, ,
or
keys to scroll to the desired current limit.
5. Press
SET
to exit from output settings mode.
Once in Set Mode (enter Set Mode by pressing the
SET
key), the active channel cannot be
changed. If Set Mode was inadvertently entered or entered in on the wrong channel, press the
SET key until the blinking cursor disappears to exit Set Mode (once out of Set Mode, active
channel switching is enabled).
Editing voltage and current values using the SET key cannot be canceled with the MENU key (the
values are immediately committed). Enter the old values by repeating the editing procedure and
manually using the
▲
,
▼
, ,
or
keys to scroll to the desired output voltage or current value(s).
SET key: This key is active in any front-panel menu or display mode - if not already in the output
settings mode, the SET key will select it.
Pressing the
SET
key to exit the output settings mode returns the instrument to the previous
display mode or front-panel menu.
V and I DACs are updated in real time - if the output is on, the output is updated immediately when
a value is altered.
If the display mode is set to DUAL V AND I, then entering SET mode will cause the display to exit
back into the SINGLE V AND I mode for the active channel. If dual is desired, select dual after
exiting set mode (see
V and I display modes (Single or Dual)
).
Editing shortcuts
The following editing shortcuts can be used when the output is OFF:
• Output voltage can be quickly set to the maximum value by incrementing the tens digit
(MSD). Note that if the tens digit is zero, it is not displayed. Place the cursor to the left of the
units digit.
• Output voltage can be quickly set to zero (0.000 V) by decrementing the first leading zero of
the reading. If there is no leading zero, decrement the tens digit.
• Current limit can be quickly set to its maximum value by incrementing the units digit (MSD).
NOTE
See
Table 1-3
for an illustration of the menu structure. Rules to navigate the
menu follow the table.
NOTE
The following steps assume that the appropriate current range is already
selected along with current limit mode and voltage protection.
▲
▲
▲
▲
▲
▲
▲
▲
Summary of Contents for 2308
Page 2: ......
Page 12: ...This page left blank intentionally...
Page 32: ...This page left blank intentionally...
Page 106: ...This page left blank intentionally...
Page 140: ...This page left blank intentionally...
Page 208: ...This page left blank intentionally...
Page 220: ...This page left blank intentionally...