2308-900-01 Rev. A / July 2008
Return to
Section Topics
1-13
Model 2308 Portable Device Battery/Charger Simulator User’s Manual
Section 1: Getting Started
Table 1-4
Main MENU structure
Menu item
Description
Ref
GPIB ADDRESS
CURRENT RANGE #1/#2
NPLC RATE #1/#2
AVER READINGS #1/#2
SAVE SETUP
RECALL SETUP
POWER ON SETUP
CALIBRATE UNIT
VOLT PROTECT #1/#2
CURR LIM MODE #1/#2
AUTO ZERO STATE
OUTPUT RELAYS
REVISION NUMBER
SERIAL NUMBER
VFD BRIGHTNESS
OUT BANDWIDTH #1/#2
OUT IMPEDANCE #1
Set primary address (0 to 30)
Select current range:
Battery channel (#1) Charger channel (#2)
5 A
5 A
500 mA 5 mA
50 mA AUTO
5 mA
AUTO
Set integration rate in NPLC (0.002 to 10)
Set average reading count (1 to 10)
Save present setup in memory (SAV0–SAV3)
Recall setup from memory (RST, SAV0–SAV3).
Select power-on setup (RST, SAV0–SAV3)
Calibrate unit (see
Calibration
)
Set voltage protection range (0–8 V) and clamp (ON/OFF)
Select current limit mode (LIMit or TRIP)
Set auto zero state (ON/OFF)
Close (1) or open (0) relay control circuitry
Display firmware revision levels
Display serial number of the power supply
Set VFD display’s brightness level (OFF, FULL, 3/4, 1/2, 1/4)
Set bandwidth (HIGH, LOW)
Set battery channels impedance (0–1
Ω
)
Sect. 6
Sect. 2
Sect. 2
Sect. 2
Note 1
Note 1
Note 1
Sec. 13
Sect. 2
Note 2
Sect. 9
Sect. 5
Note 2
Note 3
Sect. 10
Sect. 2
Sect. 2
PULSE CURRENT #1/#2
HIGH TIME
LOW TIME
AVERAGE TIME
AUTO TIME
PULSE TIMEOUT
AVERAGE READINGS
TRIGGER DELAY
TRIGGER LEVEL
Pulse-current configuration.
Set high time integration rate (in µsec.).
Set low time integration rate (in µsec.).
Set average time integration rate (in µsec.).
Set pulse integration rates automatically.
Set pulse timeout (default is 1.000 second, incremented in
1ms steps)
Set average reading count (1 to 100).
Set trigger delay in seconds (0 to 100 msec).
Sets pulse current trigger level in Amps for the 5 A, 500 mA,
50 mA, or 5 mA current ranges:
Battery channel (#1) Charger channel (#2)
A(5.0) 0–5A in 5 mA steps A(5.0) 0–5 A in 5 mA steps
mA(500) 0–500 mA in 0.5 mA steps
mA (50) 0-50 mA in 0.05 mA steps
mA (5) 0-5 mA in 0.005 mA steps
Sect. 3
The main menu structure is accessed by pressing the
MENU
key on the front panel.
Notes:
1. See
Default settings
in this section to save and recall setups.
2. Revision Number displays the firmware revision level for the microcontroller and the display.
3. Serial Number displays the serial number of the power supply.
Summary of Contents for 2308
Page 2: ......
Page 12: ...This page left blank intentionally...
Page 32: ...This page left blank intentionally...
Page 106: ...This page left blank intentionally...
Page 140: ...This page left blank intentionally...
Page 208: ...This page left blank intentionally...
Page 220: ...This page left blank intentionally...