– 3 –
3. INSTALLATION
3-1. Removing the bed fixing bolt
Remove bed fixing bolt
❶
. This bolt is necessary
to transport the sewing machine.
3-2. Adjusting the safety switch
In the case error 302 occurs when the sewing
machine runs after setup, remove screws
❶
(six
pieces) to detach the cover. Then, loosen the
safety switch mounting screw with a screwdriver
and move safety switch
❷
downward. In this
state, adjust the safety switch.
❷
❶
❶
❶
❶
❶