– 78 –
2-6-2. Memory switch
Memory switch data are the motion data that the sewing machine has in common and the data that operate on all sewing patterns in common.
(1) How to change the memory switch data
No.
Name
Selection item
Setting
range
Unit &
Meaning
Initial value
HS3020RSZ
GS3020RSZ
HS3020RSW
GS3020RSW
U001 Max. sewing speed of the sewing
machine
200 to
2,800
100
sti/min
2,800
U002 Sewing speed for the 1st stitch of soft
start (With the thread clamp)
200 to 900
100
sti/min
900
U003 Sewing speed for the 2nd stitch of soft
start (With the thread clamp)
200 to
2,800
100
sti/min
2,800
U004 Sewing speed for the 3th stitch of soft
start (With the thread clamp)
200 to
2,800
100
sti/min
2,800
U005 Sewing speed for the 4th stitch of soft
start (With the thread clamp)
200 to
2,800
100
sti/min
2,800
U006 Sewing speed for the 5th stitch of soft
start (With the thread clamp)
200 to
2,800
100
sti/min
2,800
U008 Thread tension at the time of thread
trimming
0 to 200
1
0
U009
Setting of the tension changeover
timing at the time of thread trimming
(reference: 28 °)
Set with 4 ° (TG resolution)
+ : Advanced
- : Retarded
-24 to 16(°)
1 (°)
0
U010 Sewing speed for the 1st stitch of soft
start (Without the thread clamp)
200 to 900
100
sti/min
200
U011 Sewing speed for the 2nd stitch of soft
start (Without the thread clamp)
200 to
2,800
100
sti/min
600
U012 Sewing speed for the 3th stitch of soft
start (Without the thread clamp)
200 to
2,800
100
sti/min
1,000