![JUKI AMS-221F3020RSW/AW-3 Instruction Manual Download Page 21](http://html.mh-extra.com/html/juki/ams-221f3020rsw-aw-3/ams-221f3020rsw-aw-3_instruction-manual_2029626021.webp)
– 16 –
②
Changing over the supply voltage of the electrical box of the AW-3 device
Change the con-
nection of the black
wire according to
the supply voltage
specification.
1. Turn OFF the power switch. Wait for five min
-
utes or more.
2. Detach the cover from the electrical box of
this device.
3. Change over the connection of the connector
to the terminal block according to the supply
voltage specification.
Color of wire
(White)
Color of wire
( Black )
Input voltage
Terminal number
1
4
200V
1
5
220V
1
6
240V
Supply voltage
MC-702 electrical box, connection
terminal
Electrical box of the AW-3 device,
connection terminal
V +
V -
Black wire
White wire
200 V
200 V
0 V
4 (200 V)
1 (0 V)
220 V
220 V
0 V
5 (220 V)
1 (0 V)
230 V
230 V
0 V
6 (240 V)
1 (0 V)
240 V
240 V
0 V
6 (240 V)
1 (0 V)
NOTE : Correspondence table of the supply voltage and the voltage changeover