Goodrive300-LIFT series inverter
Commissioning guidelines
-88-
Function
code
Name
Recommended
value
Remarks
HDI terminal
3
Maintenance
Y output
1
Running feedback output
Relay 1 output
4
Fault output (EO)
Relay 2 output
7
Brake control (FC)
Relay 3 output
8
Contactor control (TC)
Brake close delay
0.1s
Brake release delay
0.10s
Brake feedback
detection time
2.0
Contactor feedback
detection time
2.0
Braking frequency
0.05Hz
Inverter stop delay
0.10s
Open-loop start
brake open
frequency of
asynchronous motor
0.0 Hz
Multi-step speed 0
0 (speed of zero)
Set based on user control requirements.
The speed of step 0 is set to 0 m/s.
Multi-step speed 1
Leveling speed
Multi-step speed 2
Emergency speed
Multi-step speed 3
Common low
speed
Multi-step speed 4
Inspection speed
Multi-step speed 5
Reserved
Multi-step speed 6
Reserved
Multi-step speed 7
Common high
speed
S-curve ACC start
segment duration
2.0s
Adjusted based on onsite
commissioning
S-curve ACC end
segment duration
2.0s
ACC time
2.0s
S-curve DEC start
segment duration
2.0s
S-curve DEC end
2.0s