Goodrive300-LIFT series inverter
Function parameters
-58-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P08.12
Faulty relay
action during
auto fault reset
0x00
–
0x11
LED ones:
0: Action during undervoltage
1: No action during undervoltage
LED tens:
0: Action during auto fault reset
1: No action during auto fault reset
0x00
○
P08.13
Auto fault reset
interval
0.1
–
100.0s
0.1s
○
P08.14
Braking
frequency during
stop
0.00
–
5.00Hz
0.00Hz
○
P08.15
Inverter stop
delay
0.00
–
5.00s
0.10s
◎
P08.16
Current
withdrawal time
during stop
0.00
–
5.00s
0.20s
◎
P08.17
Modulation
0: 2PH modulation
1: 3PH modulation
1
◎
P08.18
Overmodulation
validity
0: Invalid
1: Valid
1
◎
P08.19
FDT1 electrical
level detection
value
0.00
0.20Hz
○
P08.20
FDT1 lag
detection value
0.0
–
100.0% (FDT1 electrical level)
0.0%
○
P08.21
Frequency
arrival detection
amplitude
0.00
0.00Hz
○
P08.22
Cooling fan
running mode
0: Normal mode
1: The fan keeps running after power on
0
○
P08.23
Enable light-load
direction search
0: Disabled
1: Enable auto running
2: Enable the function of providing the running
direction
0
◎
P08.24
Light-load
direction
detection time
0.000
–
5.000s
2.000s
◎