Goodrive300-LIFT series inverter
Peripheral optional parts
-168-
terminal (-) must be no more than 5 meters. Both the length of the cable
connecting BR1 to one brake resistor terminal and length of the cable
connecting BR2 to the other brake resistor terminal must be no more than 10
meters.
Signal-inverter connection
+ +
+ +
+
+
+
External brake
resistor RB
(+)
DC+
(-)
DC-
BR1 BR2
PE
(-)
(+)
+
+ + + + +
+
GD300L
DBU
brake unit
D.9
Emergency operation systems
The table below lists emergency operation systems, which can be purchased as required.
No.
Name
Model
Function
1
Storage battery
protection board
ASY01_PA1602_CV1
Installs diodes D1 and D2 to protect the
storage battery.
2
Control power board
ASY01_PA0001_PW1
Boosts the UPS power to power the
control board in emergency operation.
3
Connection cable
1 meter
Connects the drive board to the control
power board.