Goodrive300-LIFT series inverter
Precautions for quick application
-6-
inside the cabinet.
2. Whether the ambient temperature in application is lower than
–
10°C. If yes, configure a
heating device.
Note:
If the inverter is installed in a cabinet, the ambient temperature is the air temperature
inside the cabinet.
3. Whether the altitude on the site is higher than 1000 m. If yes, derate the machine by 1% for
every increased 100 m.
4. Whether the ambient humidity is higher than 90% or condensation occurs. If yes, take extra
protective measures.
5. Whether there is direct sunlight or biological invasion in the application environment. If yes,
take extra protective measures.
6. Whether there is dust or inflammable and explosive gas in the application environment. If
yes, take extra protective measures.
2.5
Installation confirmation
Check the following items after the installation of the inverter is complete.
1. Whether the input power cables and motor cables meet the current-carrying capacity
requirements of the actual load.
2. Whether the peripheral accessories are correctly selected and properly installed, and
whether the installation cables meet the current-carrying capacity requirements of the
accessories, including the input reactor, input filter, output reactor, output filter, DC reactor,
brake unit, and brake resistor.
3. Whether the inverter is installed on non-flammable materials, and whether its heat-emitting
accessories (such as reactor and brake resistor) are kept away from inflammable materials.
4. Whether all the control cables are wired separately from power cables, and whether
electromagnetic compatibility (EMC) specification requirements are taken into full account
during the wiring.
5. Whether all the grounding systems are properly grounded according to the requirements of
the inverter.
6. Whether all the installation spacings of the inverter meet the requirements stated in the
manual.
7. Whether the installation of the inverter meets the requirements stated in the manual.
8. Check that the external connection terminals are tightly fastened and whether the torque
meets the requirements.
9. Whether screws, cables, or other conductive items drop into the inverter. If yes, take them
out.