Goodrive300-LIFT series inverter
Function parameters
-51-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
machine.
5: Save function parameters (including motor
parameters) of the machine
Note
: After completing the 1
–
5 operations, the
parameter is automatically reset to 0. The
upload and download functions are invalid for
the factory parameters in P29.
Tens place:
Indicates the parameter group to be uploaded or
downloaded. You can set four groups.
Thousands place:
Indicates the response speed of the keypad
0: Low speed
1: Medium speed
2: High speed
P07.02
Reserved
Reserved
0
◎
P07.03
Keypad
0: External keypad
1: Local keypad
2: Both external keypad and local keypad are
valid.
2
○
P07.04
QUICK/JOG
function
selection
0: No function
1: Reserved
2: Shift the display state by the shifting key.
3: Shift between forward rotations and reverse
rotations.
4: Clear UP/DOWN settings.
5: Coast to stop.
6
:
Reserved
7: Quick commissioning mode (based on
non-factory parameter settings)
7
◎
P07.05
STOP/RST
function
selection
0: Only valid for the keypad control
1: Valid for both keypad and terminals control
2: Valid for both keypad and communication
control
3: Valid for all control modes
0
○