Goodrive300-LIFT series inverter
Technical data
-153-
B.4.1 EMC compatibility and motor cable length
To comply with the European EMC Directive (standard 2004/108/EC), use the following maximum
motor cable lengths for 4 kHz switching frequency.
All frame sizes (with external EMC filter)
Maximum motor cable length, 4 kHz
Second environment (category C3)
30
First environment (category C2)
30
Maximum motor cable length is determined by the drive's operational factors. Contact the local
representative for the exact maximum lengths when using external EMC filters.
For details about environment categories C3 and C2, see "EMC regulations".
B.5
Applicable standards
The inverter complies with the following standards:
EN/ISO 13849-1:2008
Safety of machinery-safety related parts of control systems -
Part 1: general principles for design
IEC/EN 60204-1:2006
Safety of machinery. Electrical equipment of machines. Part 1:
General requirements.
IEC/EN 62061:2005
Safety of machinery
–
Functional safety of safety-related
electrical, electronic and programmable electronic control
systems
IEC/EN 61800-3:2004
Adjustable speed electrical power drive systems. Part 3: EMC
requirements and specific test methods
IEC/EN 61800-5-1:2007
Adjustable speed electrical power drive systems
–
Part 5-1:
Safety requirements
–
Electrical, thermal and energy
IEC/EN 61800-5-2:2007
Adjustable speed electrical power drive systems
–
Part 5-2:
Safety requirements. Functional.
B.5.1 CE marking
The CE mark is attached to the inverter to state that the inverter follows the provisions of the
European Low Voltage (2006/95/EC) and EMC Directives (2004/108/EC).
B.5.2 Compliance with the European EMC Directive
The EMC Directive defines the requirements for immunity and emissions of electrical equipment used
within the European Union. The EMC product standard (EN 61800-3:2004) covers requirements
stated for drives. See section
EMC regulations
.
B.6
EMC regulations
EMC product standard (EN 61800-3:2004) contains the EMC requirements to the inverter.
First environment: domestic environment (includes establishments connected to a low-voltage