Goodrive300-LIFT series inverter
Function parameters
-55-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P07.37
Previous 9 fault
type
41
–
42: Reserved
43: Motor overtemperature fault (OT)
44: Reserved
45: Braking fault (BAE)
46: Contactor fault (CONE)
47: No CD signal (nPoS)
48: No enabling signal (U-EN)
49: STO card fault (SAFE)
50: Channel 1 (STO1_FB_DSP) safety circuit
exception (STL1)
51: Channel 2 (STO1_FB_DSP) safety circuit
exception (STL2)
52: Internal circuit exception (STL3)
53: Safety code FLASH CRC fault (CrCE)
P07.38
Running
frequency at
current fault
0.00Hz
●
P07.39
Ramp reference
frequency at
current fault
0.00Hz
●
P07.40
Output voltage
at current fault
0V
●
P07.41
Output current at
current fault
0.0A
●
P07.42
Bus voltage at
current fault
0.0V
●
P07.43
Max.
temperature at
current fault
0.0
˚C
●
P07.44
Input terminals
state at current
fault
0
●
P07.45
Output terminals
state at current
fault
0
●
P07.46
Running
frequency at last
fault
0.00Hz
●