Goodrive300-LIFT series inverter
Commissioning guidelines
-84-
Function
code
Name
Recommended value
Remarks
S2 function selection
2
Downward running (REV)
S3 function selection
19
Inverter enabling (ENA)
S4 function selection
8
Multi-step speed terminal 1
(MS1)
S5 function selection
9
Multi-step speed terminal 2
(MS2)
S6 function selection
10
Multi-step speed terminal 3
(MS3)
S7 function selection
17
Contactor feedback (TB)
S8 function selection
18
Brake feedback (FB)
S9 function selection
6
Fault reset (RET)
HDI terminal
3
Maintenance
Y output
1
Running feedback output
Relay 1 output
4
Fault output (EO)
Relay 2 output
7
Brake control (FC)
Relay 3 output
8
Contactor control (TC)
Brake close delay
0.1s
Brake release delay
0.10s
Brake feedback
detection time
2.0
Contactor feedback
detection time
2.0
Inverter stop delay
0.10s
Multi-step speed 0
0 (Zero speed)
Set based on user control
requirements. The speed of step
0 is set to 0 m/s.
Multi-step speed 1
Re-leveling speed
Multi-step speed 2
Creeping speed
Multi-step speed 3
Emergency speed
Multi-step speed 4
Reserved
Multi-step speed 5
Normally low speed
Multi-step speed 6
Normally high speed 1
Multi-step speed 7
Normally high speed 2
S-curve ACC start
segment duration
2.0s
Adjusted based on the onsite
commissioning
S-curve ACC end
segment duration
2.0s