Goodrive300-LIFT series inverter
Peripheral optional parts
-158-
Appendix D Peripheral optional parts
D.1
What this chapter contains
This chapter describes how to select the options and parts of GD300L series.
D.2
Peripheral wiring
Below is the peripheral wiring of GD300L series.
Power supply
Breaker
Input filter
Input reactor
Earth
DC reactor
LED keypad LCD keypad
Standard
Optional
P1
+
+
-
PB
Brake
resistor
Brake unit
PC
RS485-
RS232
converter
Output filter
Output reactor
Motor
Earth
+
Upper computer
software
485 +
485-
Note
:
The inverters of 380V (≤15kW) are embedded with
brake units. The inverters of 380V
(≥18.5kW) support optional
brake units.
Brake units are INVT standard brake units. Refer to the instruction of DBU for details.