Goodrive300-LIFT series inverter
Keypad operation procedure
-32-
5.4.1 How to modify the function codes of the inverter
The inverter has three levels menu, which are:
1. Group number of function code (first-level menu)
2. Tab of function code (second-level menu)
3. Set value of function code (third-level menu)
Remarks: Press both PRG/ESC or DATA/ENT to return to the second-level menu from the third-level
menu. The difference is: pressing DATA/ENT will save the set parameters into the control panel, and
then return to the second-level menu with shifting to the next function code automatically; while
pressing PRG/ESC will directly return to the second-level menu without saving the parameters, and
keep staying at the current function code.
Under the third-level menu, if the parameter has no blinking bit, it means the function code cannot be
modified. The possible reasons could be:
1) This function code is not modifiable parameter, such as actual detected parameter, operation
records and so on;
2) This function code is not modifiable in running state, but modifiable in stop state.
Example: Set function code
from 0 to 1.
The units place is
blinking.
All digits are
blinking.
The units place is
blinking.
The units place is blinking.
The units place is blinking.
Note:
When setting the value, you can press and + to modify the value.
PRG
ESC
DATA
ENT
PRG
ESC
PRG
ESC
PRG
ESC
DATA
ENT
DATA
ENT
Figure 5-3 Sketch map of modifying parameters
5.4.2 How to set the password of the inverter
Goodrive300L series inverters special for lifts provide password protection function to users. Set
to gain the password and the password protection becomes valid instantly after quitting from
the function code editing state. Press PRG/ESC again to the function code editing state, "0.0.0.0.0"
will be displayed. Unless using the correct password, you cannot enter it.
Set
to 0 to cancel password protection function.
The password protection becomes effective 1 minute later after retreating from the function code
editing state. Press PRG/ESC again to the function code editing state, "0.0.0.0.0" will be displayed.
Unless using the correct password, you cannot enter it.