Goodrive300-LIFT series inverter
Function parameters
-39-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P01.06
ACC/DEC
selection
Changing mode of the frequency during start-up
and running.
0: Linear type
The output frequency increases or decreases
linearly.
f
max
Output frequency (f)
t1
t2
Time (t)
1: S curve, indicating the output frequency
increases or decreases according to the S
curve.
Generally, S curve is used in scenarios such as
lifts and conveyers which require smooth startup
and stop.
Output frequency (f)
Time (t)
f
max
t1
t2
0
◎
P01.07
Stop mode
0: Decelerate to stop. After the stop command
becomes valid, the inverter decelerates to
decrease the output frequency during the set
time. When the frequency decreases to
the inverter stops.
1: Coast to stop: after the stop command
becomes valid, the inverter ceases the output
immediately. And the load coasts to stop at the
mechanical inertia.
0
○
P01.08 Start frequency
in stop braking Starting frequency of stop braking: The inverter
will carry on stop DC braking when the
frequency is arrived during decelerating to stop.
Demagnetizing time: Before the stop DC
0.00Hz
○
P01.09 Demagnetizing
time
0.00s
○
P01.10 Stop DC braking
current
0.0%
○