Goodrive300-LIFT series inverter
Function parameters
-40-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P01.11 DC braking time
braking, the inverter will close output and begin
to carry on the DC braking after the waiting time.
This function avoids the overcurrent fault caused
by DC braking when the speed is too high.
Stop DC braking current: DC brake added.
Stronger current indicates bigger DC braking
effect.
Braking time of stop braking: Retention time of
DC brake. If the time is 0, the DC brake is
invalid. The inverter will stop at the set
deceleration time.
Running
command
Pre-start
braking
command
Constant speed
ON
OFF
Braking waiting time
during stop
Time t
ACC
DEC
DC braking at stop
Setting range of
: 0.00Hz
(max.
output frequency)
Setting range of
: 0.00
–
30.00s
Setting range of
: 0.0
–
100.0%
Setting range of
: 0.0
–
50.0s
0.0s
○
P01.12 Stop knee-point
frequency
0.00
–
10.00Hz
In the process of deceleration to stop, the stop
deleration curve starts after the frequency set in
this parameter is reached.
1.00Hz
○
P01.13
Startup delay
The function determines the brake release after
the running command is given, and the inverter
is in a stand-by state and waits for the delay time
set by
Setting range: 0.00
–
60.00s
0.04s
○
P01.14
Reserved
0
–
65535
0
○
P01.15
Reserved
0
–
65535
0
○