Goodrive300-LIFT series inverter
Function parameters
-49-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P06.03
HDO output
3: Down operation
4: Fault output
5: Zero speed running
6: Ready for running
7: Braking control
8: Contactor control
9: Frequency arrival
10: Frequency detection threshold (FDT) output
11: FDT reverse output
12: Reserved
13: Light-load direction detection completed
14: Down as the light-load direction detection
result
15: Up as the light-load direction detection result
16: Running 1 (excluding current withdrawal)
17: STO opereation
18: SPI fault output
19: UPS control signal output (for India)
20: Reserved
0
○
P06.04
Relay output
RO1
4
○
P06.05
Relay output
RO2
7
○
P06.06
Relay output
RO3
8
○
P06.07
Relay RO4
output
0
○
P06.08
Polarity of output
terminals
The function code is used to set the pole of the
output terminal.
If the current bit is set to 0, output terminal is
positive. If the current bit is set to 1, output
terminal is negative.
BIT6
BIT5
BIT4
RO4
RO3
RO2
BIT3
BIT2
BIT1
BIT0
RO1
HDO
Y2
Y1
Setting range: 0x0
–
0x7F
00
○
P06.09
AO1 output
0: Running speed
1: Set speed
2: Running rotation speed
3: Output current
4: Output voltage
5: Output power
6: Output torque
7: AI1 input value
8: AI2 input value
9
–
14: Reserved
0
○
P06.10 HDO high-speed
pulse output
0
○
P06.11
AO1 output
lower limit
The above function codes define the relative
relationship between the output value and
0.0%
○
P06.12
AO1 output of
lower limit
0.00V
○