Goodrive300-LIFT series inverter
Commissioning guidelines
-93-
inverter stops, and outputs contactor releasing command and lift stop signal (Y1). By now, one
operation cycle ends.
7.5.5 Distance control
Function
code
Name
Recommended value
Remarks
Pulley diameter
100
–
2000mm
500mm
DEC ratio
0.50
–
50.00
1.00
control
0x00
–
0x11
Ones place: Enable control over the distance
between high-speed running and creeping
0: Disabled; 1: Enabled
Tens place: Enable control over the distance
between creeping and stop
0: Disabled; 1: Enabled
0
High-speed running
DEC distance
0.200-3.000m
1.800
Medium- and
low-speed DEC
distance
0.100-3.000m
1.000
DEC distance for
creeping to stop
0.010-1.000m
0.080
UP DEC adjustment
distance
-0.300
–
0.300m
0.000
Down DEC
adjustment distance
-0.300
–
0.300m
0.000
High-speed step of
multi-step speed
running
0
–
7
3
Medium- and
low-speed step of
multi-step speed
running
0
–
7
1
Creeping step of
multi-step speed
running
0
–
7
0