Goodrive300-LIFT series inverter
Function parameters
-70-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
The function code is used to set the Ethernet
communication speed.
P16.01 IP address 1
0
–
255
Set the IP addresses in Ethernet
communication.
IP address format:
IP address example: 192.168.0.1
192
◎
P16.02 IP address 2
168
◎
P16.03 IP address 3
28
◎
P16.04 IP address 4
11
◎
P16.05 Subnet mask 1
0
–
255
Set the subnet masks in Ethernet
communication.
Subnet mask format:
Subnet mask example: 255.255.255.0
255
◎
P16.06 Subnet mask 2
255
◎
P16.07 Subnet mask 3
255
◎
P16.08 Subnet mask 4
0
◎
P16.09 Gateway 1
0
–
255
Set the gateways in Ethernet communication.
192
◎
P16.10 Gateway 2
168
◎
P16.11 Gateway 3
28
◎
P16.12 Gateway 4
1
◎
P16.13 Reserved
0
–
65535
0
●
P16.14 Reserved
0
–
65535
0
●
P17 Group Monitoring function
P17.00 Set frequency
Display current set frequency of the inverter
Setting range: 0.00Hz
0.00Hz
●
P17.01
Output
frequency
Display the current output frequency of the
inverter.
Setting range: 0.00Hz
0.00Hz
●
P17.02
Ramp reference
frequency
Display current ramp given frequency of the
inverter.
Setting range: 0.00Hz
0.00Hz
●
P17.03 Output voltage
Display current output voltage of the inverter.
Setting range: 0
–
1200V
0V
●
P17.04 Output current
Display current output current of the inverter.
Setting range: 0.0
–
5000.0A
0.0A
●