Goodrive300-01A series VFD for air compressor
Function description
-82-
Function
code
Name
Description
Default
Modify
P18.32
PT2 calibration
voltage 1 (20
℃
)
It is used to calibrate temperature detection
circuit before shipment.
Connect to the resistor whose resistance is
the same with that of PT100 at 20°C, read
the voltage value of
Connect to the resistor whose resistance is
the same with that of PT100 at 120°C, read
the voltage value of
Setting range: 0.00
–10.00V
Note:
1. This value will stay in currently set value
when restoring to default values.
2. PT2 is on the expansion card, so P18.32
and P18.33 make sense only when an
expansion
card
is
connected.
If
no
expansion
card
is
connected,
both
parameters are 0.
3.41V
○
P18.33
PT2 calibration
voltage 2 (120
℃
)
7.42V
○
P18.34
Auxiliary
temperature
protection
enabling
0: Disable
1: Enable
0
◎
P18.35
Auxiliary
temperature
pre-alarm
-20
–150
When
temperature is higher than
, the
system
indicates
auxiliary
temperature
pre-alarm by setting BIT8 of
to 1.
105
℃
○
P18.36
Auxiliary
temperature alarm
-20
–150
When
temperature is higher than
, the
system indicates auxiliary temperature alarm
by setting BIT10 of
emergency-stop will be applied.
110
℃
○
P18.37
Pressure sensor
channel
0: Discharge pressure P1, auxiliary pressure
P2
1: Discharge pressure P2, auxiliary pressure
P1
0
◎