Goodrive300-01A series VFD for air compressor
Function description
-63-
Function
code
Name
Description
Default
Modify
(Direct-axis inductance of SM 1) and P02.22
(Quadrature-axis inductance of SM 1) are
used in the calculation.
1: Disable
Applicable to embedded/surface-mounted
synchronous motors. The actual value of
P02.21 (Direct-axis inductance of SM 1) is
used in the calculation.
Note:
The optimization mode can be
enabled/disabled according to the field on
site.
P08.28
Auto fault reset
count 1
0
–10
5
○
P08.29
Auto fault reset
interval 1
0.1
–3600.0s
5.0s
○
P08.30
Frequency
decrease ratio
in drop control
0.00
–50.00Hz
0.00Hz
○
P08.32
FDT1 electrical
level detection
value
0.00
–P00.03 (max. output frequency)
50.00Hz
○
P08.33
FDT1 lagging
detection value
-100.0
–100.0% (FDT1 electrical level)
5.0%
○
P08.34
FDT2 electrical
level detection
value
0.00
–P00.03 (max. output frequency)
50.00Hz
○
P08.35
FDT2 lagging
detection value
-100.0
–100.0% (FDT2 electrical level)
5.0%
○
P08.36
Detection value
for frequency
being reached
0.0
–P00.03 (max. output frequency)
0.00Hz
○
P08.39
Running mode
of cooling fan
0: Common running mode
1: The fan keeps running after power-on
2: Control based on temperature
0
○
P08.40
PWM selection
0x00
–0x21
LED ones: PWM mode selection
0: PWM mode 1, 3PH modulation and 2PH
01
◎