Goodrive300-01A series VFD for air compressor
External optional accessories
-141-
03.17 16:02:35
Home
Air filter set time xxxxxx h
Return
Edit
Maintain param
Oil filter set time xxxxxx h
Splitter set time xxxxxx h
Lubricat Oil set time xxxxxx h
Grease set time xxxxxx h
Air filter run time xxxxxx h
03.17 16:02:35
Home
Grease run time xxxxxx h
Return
Edit
Maintain param
Air filter run time xxxxxx h
Oil filter run time xxxxxx h
Splitter run time xxxxxx h
Lubricat Oil run time xxxxxx h
Grease set time xxxxxx h
Figure B-24 Maintenance parameter interface
Maintenance
parameter
Initial
value
Function
Air filter set time
0
If the accumulative air filter use time exceeds this value, a
pre-alarm is displayed. If this value is set to 0, no pre-alarm
is displayed.
Oil filter set time
0
If the accumulative oil filter use time exceeds this value, a
pre-alarm is displayed. If this value is set to 0, no pre-alarm
is displayed.
Splitter set time
0
If the accumulative splitter use time exceeds this value, a
pre-alarm is displayed. If this value is set to 0, no pre-alarm
is displayed.
Lubricate oil set
time
0
If the accumulative lubrication oil use time exceeds this
value, a pre-alarm is displayed. If this value is set to 0, no
pre-alarm is displayed.
Grease set time
0
If the accumulative grease use time exceeds this value, a
pre-alarm is displayed. If this value is set to 0, no pre-alarm
is displayed.
Air filter run time
/
It is cleared when a new air filter is used.
Summary of Contents for GD300-01A