Goodrive300-01A series VFD for air compressor
External optional accessories
-132-
03.17 16:02:35
Enter
PMSM air compressor system
Software ver:V1.00
ConfigTB ver:V1.00
Figure B-10 Initial interface
B.2.4.2 Working environment interface
The working environment interface displays certain parameters about the running.
03.17 16:02:35
Set
Alarm
Menu
Workspace
Output Freq
P17.01
Hz
0.00
Present Pressure
P19.11
0.00
25
Mpa
Present Temp
P19.12
Ready
Device Status
Set
Alarm
Menu
0
Accumulated Run Time
P19.16
h
Figure B-11 Working environment
Parameter
Description
Device status
Ready: indicates the device is not started and it does not encounter an alarm.
Only when the device is in standby state, the device can be started and the device
startup key is valid.
Run: indicates that the device is started and does not encounter an alarm.
Fault: indicates that the master VFD or fan VFD encounters a fault. The fault
alarm is cleared only after the fault is handled.
Emergency stop: indicates that the emergency stop key is pressed. It is cleared
only after the emergency stop key is reset.