Goodrive300-01A series VFD for air compressor
Function description
-49-
Function
code
Name
Description
Default
Modify
Setting range: 0x00
–0xFF
P05.11
Digital input
filter time
0.000
–1.000s
0.100s
○
P05.12
Virtual
terminal
setting
0: Virtual terminals are invalid
1: Modbus communication virtual terminals
are valid
2
–4: Reserved
0
◎
P05.13
Terminal
control mode
0: 2-wire control 1
1: 2-wire control 2
2: 3-wire control 1
3: 3-wire control 2
0
◎
P05.14
S1 switch-on
delay
0.000
–50.000s
0.000s
○
P05.15
S1 switch-off
delay
0.000
–50.000s
0.000s
○
P05.16
S2 switch-on
delay
0.000
–50.000s
0.000s
○
P05.17
S2 switch-off
delay
0.000
–50.000s
0.000s
○
P05.18
S3/PTC
terminal
switch-on delay
0.000
–50.000s
0.000s
○
P05.19
S3/PTC
terminal
switch-off delay
0.000
–50.000s
0.000s
○
P05.20
S4 switch-on
delay
0.000
–50.000s
0.000s
○
P05.21
S4 switch-off
delay
0.000
–50.000s
0.000s
○
P05.22
S5 switch-on
delay
0.000
–50.000s
0.000s
○
P05.23
S5 switch-off
delay
0.000
–50.000s
0.000s
○
P05.24
S6 switch-on
delay
0.000
–50.000s
0.000s
○
P05.25
S6 switch-off
delay
0.000
–50.000s
0.000s
○
Summary of Contents for GD300-01A