Goodrive300-01A series VFD for air compressor
Communication protocol
-172-
Function
description
Address
definition
Data meaning
R/W
characteristics
forward rotating (0
–Fmax (unit: 0.01Hz))
2006H
The set value of upper limit frequency of
reverse rotating (0
–Fmax (unit: 0.01Hz))
R/W
2007H
Upper limit torque of electromotion torque
(0
–3000, 1000 corresponds to 100.0% of
motor current of the VFD)
R/W
2008H
Upper limit torque of brake torque (0
–
3000, 1000 corresponds to 100.0% of
rated motor current)
R/W
2009H
Special control command word:
Bit0
–1: =00: Motor 1 =01: Motor 2
=10: Motor 3 =11: Motor 4
Bit2: =1 Torque control =0: Speed control
Bit3: =1 Power consumption cleared to
zero =0: Power consumption not cleared to
zero
Bit4: =1 Pre-excitation =0: Pre-excitation
forbidden
Bit5: =1 DC brake =0: DC brake forbidden
R/W
200AH
Virtual input terminal command, range:
0x000
–0x1FF
R/W
200BH
Virtual output terminal command, range:
0x00
–0x0F
R/W
200CH
The set voltage value (used for V/F
separation)
(0
–1000, 1000 corresponds to 100.0%
rated motor voltage)
R/W
200DH
The set value 1 of AO output (-1000
–1000,
1000 corresponds to 100.0%)
R/W
200EH
The set value 2 of AO output (-1000
–1000,
1000 corresponds to 100.0%)
R/W
200FH
BIT0: =1 running time of part 1 cleared to
zero; =0: invalid
BIT1: =1 running time of part 2 cleared to
zero =0: invalid
BIT2: =1 running time of part 3 cleared to
zero =0: invalid
R/W