Goodrive300-01A series VFD for air compressor
Function description
-36-
Function
code
Name
Description
Default
Modify
P00.06
Setting channel
of A frequency
command
0: Keypad
1: Analog P1-
2: Reserved
3: Analog P2-
4: Reserved
5: Reserved
6: Multi-step speed running
7: PID control
8: Modbus communication
9
–11: Reserved
Note:
A frequency and B frequency cannot
use the same frequency reference mode. You
can set the frequency source through
0
○
P00.07
Setting channel
of B frequency
command
2
○
P00.08
Reference
object of B
frequency
command
0: Max. output frequency
1: A frequency command
0
○
P00.09
Combination
mode of setting
source
0: A
1: B
2: (A+B)
3: (A- B)
4: Max(A, B)
5: Min. (A, B)
0
○
P00.10
Frequency set
through keypad
0.00 Hz
50.00Hz
○
P00.11
ACC time 1
0.0
–3600.0s
Model
depended
○
P00.12
DEC time 1
0.0
–3600.0s
Model
depended
○
P00.13
Running
direction
0: Run at the default direction.
1: Run at the opposite direction.
2: Disable reverse running
2
○
P00.14
Carrier
frequency
setting
1.0
–8.0kHz
Model
depended
○
Summary of Contents for GD300-01A