Goodrive300-01A series VFD for air compressor
External optional accessories
-162-
Category
Function
Specifications
Ethernet
None
USB port
1 USB Slave 2.0 port; 1 USB Host 2.0 port
Program download
method
USB Slave/U disk
Serial
communication port
COM1
:
RS232/RS485/RS422
COM2: RS485
COM3: RS232
Viewing angle of
LCD
(T/B/L/R)
50'/70'/70'/70'
Electrical
performance
Rated power
< 10W
Rated voltage
DC24V, allowable working range DC 9V
–28V
Power supply
protection
Surge protection capability
Allowed power
outage
< 5ms
CE & RoHS
Compliant with EN61000-6-2:2005 and
EN61000-6-4:2007
Compliant with RoHS lightning surge ±1kV, group pulse
±2kV
Static contact 4kV, air discharge 8kV
Environment
requirement
Working
temperature
0
–50
℃
Storage
temperature
-20
–60
℃
UV resistance
Disallowed to work under strong UV (such as direct
sunlight)
Ambient humidity 10
–90%RH (no condensation)
Shock resistance 10
–25Hz (X, Y, Z direction 2G/30 minutes)
Cooling method
Natural air cooling
Mechanical
performance
Ingress protection
rating
The front panel reaches IP65 (installed with a flat panel
cabinet), and the rear shell of the device reaches IP20.
Mechanical
structure
Engineering plastic
Cut-out dimensions 192mm×138mm
Overall dimensions 204mm×145mm×33.8mm
Overall weight
About 560g