Goodrive300-01A series VFD for air compressor
Communication protocol
-174-
Function
description
Address
definition
Data meaning
R/W
characteristics
Bit4: =0: Non-overload pre-alarm
=1: Overload pre-alarm
Bit5
– Bit6:
=00: Keypad control
=01: Terminal control
=10: communication control
VFD fault code
2102H
See fault type
R
VFD
identification
code
2103H
GD300-01A (optional multi-function
expansion card)-----0x0132
R
Running
frequency
3000H
Compatible with CHF100A, CHV100
communication address
R
The set
frequency
3001H
R
Bus voltage
3002H
R
Output voltage
3003H
R
Output current
3004H
R
Running speed
3005H
R
Output power
3006H
R
Output torque
3007H
R
Closed- loop
setting
3008H
R
Closed- loop
feedback
3009H
R
Input IO state
300AH
R
Output IO state
300BH
R
Analog input 1
300CH
R
Analog input 2
300DH
R
Analog input 3
300EH
R
Analog input 4
300FH
R
Read high
speed pulse 1
input
3010H
R
Read high
speed pulse 2
input
3011H
R
Summary of Contents for GD300-01A
Page 1: ......
Page 187: ...6 6 0 0 1 0 0 7 6 1...