Goodrive300-01A series VFD for air compressor
External optional accessories
-131-
B.2.3.2 Cable description
Emergency
stop signal
Emergency
stop signal
Figure B-8 Emergency stop cable diagram
Note:
The emergency stop cable is used for emergency stop control when a device fault occurs and it
is often connected to the S1 terminal and COM terminal.
2500±15(m m)
48 5 +
+24 V
48 5 -
G ND
70±10(mm )
棕
棕 白
绿
蓝 白
蓝
绿 白
橙
橙 白
1
2
3
4
5
6
7
8
8
1
Figure B-9 RS485 communication cable diagram
Table B-5 Wires and terminals
Network port diagram
Terminal
Wire
Brown
Brown&white
Green
Blue&white
Blue
Green&white
Orange
Orange&white
1
2
3
4
5
6
7
8
GND
Orange&white
1
Twisted pair
Orange
2
485-
Green&white
3
3 and 6
twisted pair
4 and 5
twisted pair
Blue
4
485+
Blue&white
5
Green
6
+24V
Brown&white
7
Twisted pair
Brown
8
B.2.4 Setting parameters on the LCD keypad
B.2.4.1 Initial interface
After power-on and startup, the initial interface appears, as shown in Figure B-10. The LCD keypad
displays the product name and software version on this interface and goes to the working
environment interface three seconds later.