ioControl
58
Index
S-idx Designation
Data type
Default
Details
0x1A09 0x00 Transmit
PDO map-
ping
Number of
mapped
objects in
PDO
rw
USINT
0x02
mapping transmit PDO 10 (system
flag)
number of integrated application
objects = 2
0x01 PDO map-
ping
rw
UDINT
0x2040 0110
Index 0x2040, SubIndex 0x01
supply voltage of the system VBBS
0x02 PDO map-
ping
rw
UDINT
0x2050 0010
Index 0x2050, SubIndex 0x00
system temperature in °C
Manufacturer-specific objekts (index 0x2000���0x6FFF):
Index
S-idx Designation
Data type
Default
Details
0x2000 0x00 IO configu-
ration
Largest
sub-index
supported
ro
USINT
16
Configuration inputs/outputs
largest supported Sub-index = 32
0x01 Configuration
IN00
rw
USINT
10
0 = 0x00
3 = 0x03
6 = 0x06
7 = 0x07
9 = 0x09
10 = 0x0A
11 = 0x0B
12 = 0x0C
off Input IN00
0���10 000 mV
ratiometric 0���1000 ‰
0���20 000 µA
0���32 000 mV
binary plus switched
binary plus switched
with diagnosis
binary minus switched
0x02 Configuration
IN01
rw
USINT
10
0 = 0x00
3 = 0x03
6 = 0x06
7 = 0x07
9 = 0x09
10 = 0x0A
11 = 0x0B
12 = 0x0C
off Input IN01
0���10 000 mV
ratiometric 0���1000 ‰
0���20 000 µA
0���32 000 mV
binary plus switched
binary plus switched
with diagnosis
binary minus switched
0x03 Configuration
IN02
rw
USINT
10
0 = 0x00
3 = 0x03
6 = 0x06
7 = 0x07
9 = 0x09
10 = 0x0A
11 = 0x0B
12 = 0x0C
off Input IN02
0���10 000 mV
ratiometric 0���1000 ‰
0���20 000 µA
0���32 000 mV
binary plus switched
binary plus switched
with diagnosis
binary minus switched