ioControl
30
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen We reserve the right to make technical alterations without prior notice!
15 Aug 2017
CR2051 / page 5
CR2051
Technical data
Control systems
Test standards and regulations
CE mark
EN 61000-6-2
Electromagnetic compatibility (EMC)
Noise immunity
EN 61000-6-4
Electromagnetic compatibility (EMC)
Radiation of interference
E1 marking
*
UN/ECE-R10
Radiation of interference
Immunity with 100 V/m
ISO 7637-2
Pulse 1, severity level: IV; function state C
Pulse 2a, severity level: IV; function state A
Pulse 2b, severity level: IV; function state C
Pulse 3a, severity level: IV; function state A
Pulse 3b, severity level: IV; function state A
Pulse 4, severity level: IV; function state B
Pulse 5, severity level: III; function state C
(data valid for the 24 V system)
Pulse 4, severity level: III; function state C
(data valid for the 12 V system)
Climatic tests
EN 60068-2-30
Damp heat, cyclic
upper temperature 55°C, number of cycles: 6
EN 60068-2-78
Damp heat, constant
Test temperature 40°C / 93% RH,
Test duration: 21 days
EN 60068-2-52
Salt spray test
Severity level 3 (vehicle)
Mechanical tests
ISO 16750-3
Test VII; Vibration, random
Mounting location vehicle body
EN 60068-2-6
Vibration, sinusoidal
10���500 Hz; 0�72 mm/10 g; 10 cycles/axis
ISO 16750-3
Bump
30 g/6 ms; 24,000 shocks
Chemical resistance
ISO 16750-5:2010
AA, AB, BA, BD, CC, DB, DC, DD
Note
The EC declaration of conformity and approvals can be found at:
www�ifm�com
* in preparation