UK
ioControl
9
6 Electrical connection
6.1 General electrical connection
The supply cables and the CAN2 interface are connected via the X1 connector
on the bottom of the device� The inputs/outputs, the CAN1 interface and the CAN
supply are connected via the Deutsch connectors on the front side of the housing�
Wiring
Original Scale Drawing (MTD)
P_MZ_e100_0092
EPS Source
Product Scale Drawing
Frame Size: 80 mm x ... mm
30%
333,4%
1
3
5
6
7
2
4
8
7
8
9
10
11
1: Connector 8
2: Connector 6
3: Connector 4
4: Connection 2
5: CAN1 OUT
6: X1 - Connection cable plug
7: CAN1 IN
8: Connector 1
9: Connector 3
10: Connector 5
11: Connector 7
9
Connector area (here e�g� CR0403)
Connector
CR2050
CR2051
CR2052
Number
of poles
1
IN00 / IN08
OUT00 / OUT08
IN00 / IN04
6
2
IN01 / IN09
OUT01 / OUT09
OUT00 / OUT04
6
3
IN02 / IN10
OUT02 / OUT10
IN01 / IN05
6
4
IN03 / IN11
OUT03 / OUT11
OUT01 / OUT05
6
5
IN04 / IN12
OUT04 / OUT12
IN02 / IN06
6
6
IN05 / IN13
OUT05 / OUT13
OUT02 / OUT06
6
7
IN06 / IN14
OUT06 / OUT14
IN03 / IN07
6
8
IN07 / IN15
OUT07 / OUT15
OUT03 / OUT07
6
CAN1 IN
CAN1 interface
6
CAN1 OUT
CAN1 interface (e�g� for looping through)
6
X1
Supply voltage and CAN2 interface
6
NOTE
Wrong connection may cause damage to the device�
►
Observe the safety instructions
�