System configuration
Configure interfaces
>
via system configuration: J1939 manager
23522
In the CODESYS device tree, you will find the following entry under each PLC:
[Communication] > [CAN]
These entries are equivalent.
Attach CAN bus
► In the CODESYS device tree: Right mouse click on [Communication] > [CAN].
► Select [Add Device...].
>
Window [Add Device] appears.
► Select [Vendor:] [ifm electronic].
► In the list below: Select [ifmCANbus].
► Confirm the selection with [Add Device].
>
Close the window [Add Device] with the [Close] button.
Assign CAN interface
► In the CODESYS device tree: Double-click on [Communication] > [CAN] > [ifmCANBus].
► Tab [General] > [General] > [Network]:
assign this setting with
/
to a CAN interface.
permissible = 0...3
► Select the required value for baud rate [Baudrate (bit/s)] from the list field.
Attach J1939 manager
► In the CODESYS device tree: Right mouse click on [Communication] > [CAN] > [ifmCANBus].
► Select [Add Device...].
>
Window [Add Device] appears.
► Select [Vendor:] <All Vendors>.
► In the list below: Select [Fieldbusses] > [SAE J1939] > [J1939 Manager] > [J1939_Manager].
► Confirm the selection with [Add Device].
► Close the window [Add Device] with the [Close] button.
Set J1939 manager parameters
► In the CODESYS device tree: Double-click [Communication] > [CAN] > [J1939_Manager].
► Tab [General] > [Database] > [Database]:
select the list from the required database.
default = J1939Default
Users can use their own databases.
They must be at the following storage location:
C:\ProgramData\CODESYS\J1939 Databases
The directory
ProgramData
is hidden by default.
>
With the menu [File] > [Save Project], the values become valid.