CWDM-xxxxxCR-B 

Mux/Demux and Optical Add/Drop Multiplexer Modules 

User Guide 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Part Number 33794 

Revision B November 2021 

 

 

 

Summary of Contents for CWDM-CR-B Series

Page 1: ...33794 Rev B https www lantronix com Page 1 of 19 CWDM xxxxxCR B Mux Demux and Optical Add Drop Multiplexer Modules User Guide Part Number 33794 Revision B November 2021 ...

Page 2: ...Phone 1 952 358 3601 or 1 800 260 1312 Email techsupport transition com Sales Offices For a current list of our domestic and international sales offices go to the Lantronix web site at www lantronix com about contact Disclaimer All information contained herein is provided AS IS Lantronix undertakes no obligation to update the information in this publication Lantronix does not make and specifically...

Page 3: ... Drop Mux Connections 8 Unpacking 9 Installation 9 Safety Instructions for Rack Mount Installations 9 Front Panels 12 Add Drop Mux Front Panel 12 CWDM Mux Front Panels 12 Fiber Cable Handling Installation 13 Handling Fiber Cables 13 Installing Fiber Cables 13 Theory of Operation 14 Coarse Wave Division Multiplexing 14 Optical Add Drop Multiplexer OADM 15 CWDM Wavelength specific Optical Transceive...

Page 4: ...ngth Division Multiplexing CWDM Mux Demux 1 CWDM M551LCR B 4 Channels OSC 1510 1530 1550 1570nm Duplex LC Mux Demux 2 CWDM M947LCR B 8 Channels OSC 1470 1610nm Duplex LC Mux Demux 3 CWDM M1631LCR B 16 Channels 1310 1610nm Duplex LC Mux Demux CWDM A2A8xxLCR B Series Add Drop Mux CWDM 1 Channel with E W Lines 4 CWDM A2A831LCR B 1 Channel 1310nm port with E W lines wideband 50nm 5 CWDM A2A833LCR B 1 ...

Page 5: ...bandwidth on existing fiber infrastructure Alleviate fiber exhaustion Transmit multiple protocols over existing duplex fiber link by combining fiber outputs of multiple media converters Provide scalable bandwidth of up to 10 Gbps per channel over existing fiber links Plug and Play no configuration of CWDM components Use existing standard optical ports on switches and routers utilize Optical Line C...

Page 6: ...Drop Multiplexer Modules Application Examples The figure below shows an existing copper switch at a Central Office or Point of Presence POP converting the electrical signal to the appropriate optical wavelength The signals are then multiplexed together and sent across the fiber infrastructure At the remote side the signals are de multiplexed and sent to the customer location Figure 2 CWDM xxxxxCR ...

Page 7: ...Lantronix CWDM xxxxxCR Mux Demux User Guide 33794 Rev B https www lantronix com Page 7 of 19 CWDM Add Drop Mux Example ...

Page 8: ...Guide 33794 Rev B https www lantronix com Page 8 of 19 CWDM Mux Demux Example CWDM Add Drop Mux Connections The figure below shows Lantronix CWDM Mux Demux Add Drop Mux modules In the figure λ1 indicates Lambda 1 for one particular wavelength ...

Page 9: ...ment in an environment compatible with the maximum ambient temperature Tma specified 2 Reduced Air Flow install the equipment in a rack so that the amount of air flow required for safe operation is not compromised 3 Mechanical Loading Mount the equipment in the rack so that a hazardous condition does not occur due to uneven mechanical loading weight distribution rack balance 4 Circuit Overloading ...

Page 10: ...To install the bracket and CWDM module into a rack do the following 1 Locate the CWDM module and bracket See Figure 3 Figure 3 Bracket and CWDM Module 2 Mount the Bracket to the equipment rack using four screws as shown in Figure 4 Figure 4 Bracket Installation 3 Pull the CWDM mounting plungers fully out as shown in Figure 5 4 Slide the CWDM module into one of the slots as shown in Figure 5 Figure...

Page 11: ...Lantronix CWDM xxxxxCR Mux Demux User Guide 33794 Rev B https www lantronix com Page 11 of 19 5 Secure the CWDM module to the bracket as shown in Figure 6 Figure 6 CWDM Module Installation into Bracket ...

Page 12: ...nel is shown in Figure 7 Figure 7 Add Drop Mux Front Panel CWDM Mux Front Panels The CWDM modules have no LEDs as it does not require power The front panels are shown in Figures 8a 8b and 8c Figure 8a 4 Channel CWDM Mux Front Panel CWDM M551LCR B Figure 8b 8 Channel CWDM Mux Front Panel CWDM M947LCR B Figure 8c 16 Channel CWDM Mux Front Panel CWDM M1631LCR B ...

Page 13: ...p the connectors protective cover on when not in use Use care in handling all fiber optic connectors Visually inspect fiber ends for signs of damage Always clean and inspect fiber connectors prior to making a connection Installing Fiber Cables To install the fiber cables do the following 1 Remove the protective cover from the port See Figure 9 Figure 9 LC Port and Dust Cover 2 Locate a 2 strand fi...

Page 14: ...x the optical signal outputs from 4 or more electronic devices These signals are sent over a single optical fiber The signals are then demultiplexed into separate distinct signals for input into electronic devices at the other end of the fiber optic link See Figure 11 Figure 11 Coarse Wave Division Multiplexing Lantronix CWDM devices utilize thin film filter technology Since the CWDM devices are e...

Page 15: ...d pass through the OADM and continue in the direction of the remote site See Figure 12 Figure 12 Add Drop Module CWDM Wavelength specific Optical Transceivers Lantronix full line of media converters and switches can incorporate CWDM wavelengths with the addition of wavelength specific small form factor pluggable SFP optical transceivers or traditional fixed optical ports CWDM SFPs comply with ITU ...

Page 16: ...43 mm x Depth 9 84 250 mm x Height 1 73 44 mm Operating Temperature 20 C to 70 C Storage Temperature 40 C to 85 C Weight 0 88 lbs 0 40 kg Warranty Lifetime CWDM Mux Specifications CWDM M551LCR B Specifications Channel Wavelength ITU ITU 1 nm Center Wavelength Accuracy 0 5 nm Channel Spacing 20 nm Channel Passband bandwidth nm 6 5 nm Insertion Loss with connector 1 6dB Channel Ripple 0 3dB Isolatio...

Page 17: ...x Depth 9 84 250 mm x Height 1 73 44 mm Operating Temperature 20 C to 70 C Storage Temperature 40 C to 85 C Weight 0 9 lbs 0 41 kg Warranty Lifetime CWDM M1631LCR B Specifications Channel Wavelength ITU ITU 1 nm Center Wavelength Accuracy 0 5 nm Channel Spacing 20 nm Channel Passband bandwidth nm 6 5 nm Insertion Loss with connector 3 2dB Channel Ripple 0 3dB Isolation Adjacent 30dB Non Adjacent 4...

Page 18: ...nnected network devices to pinpoint the problem to the switch See the related documentation 5 When calculating optical loss ensure that the total loss plus a safety factor typically 3dB does not exceed the optical power budget the difference between the transmitter optical output power and the receiver s optical sensitivity See the equipment manufacturers documentation for the transmitter optical ...

Page 19: ...arters 7535 Irvine Center Drive Suite100 Irvine CA 92618 USA Toll Free 800 526 8766 Phone 949 453 3990 Fax 949 453 3995 Technical Support Online http www transition com support Sales Offices For a current list of our domestic and international sales offices go to the Lantronix web site at www lantronix com about contact ...