24
ifm
Programming Manual ecomatController/60-1 (CR711S) Operating System V2.5.0.n
2017-12-19
Installation
Carry out installation
>
4.2.4
Update the operating system of the device
Update the operating system of the device with the batch file ............................................................ 24
23501
ATTENTION
Important: During the update process, the electric voltage supply of the device must be assured.
The device may only be disconnected from the voltage supply after the data transfer/update process
is finished.
An incomplete operating system update may destroy the device!
23374
Important: Field test units cannot be updated!
► Before the update process, please ensure:
Device is connected to the voltage supply and switched on
The Ethernet interface is connected to the same network as the PC
>
Update the operating system of the device with the batch file
23825
ATTENTION
► Strictly follow the instructions on the screen during the entire update process!
>
Otherwise the controller may be destroyed!
To update the operating system of the device with the batch file
update.bat
:
► Unpack the ZIP file with the batch file
update.bat
and the corresponding files in a local
memory location.
Important: The data path in which the batch file is unpacked may not contain any blanks!
► Execute the batch file
update.bat
► Follow the instructions on the screen.
>
The [ecomatController Update Start Menu] appears.
If the device is not set to the standard IP address 192.168.82.247:
► Use the [i] key to select the menu item [Set device ip-address].
► Enter the IP address set in the device and confirm with [RETURN].
>
The IP address setting in the batch program has been changed.
► Use the [P] key to call up the menu item [Ping device]
>
The ping command is executed. The device must answer to the ping request to enable an
update process.
If ping is successful: