128
ifm
Programming Manual ecomatController/60-1 (CR711S) Operating System V2.5.0.n
2017-12-19
ifm function libraries
Library ifmIOcommon.library
>
10.5.2
Output
23161
Function block type:
Function block (FB)
Library:
ifmIOcommon.library
Symbol in CODESYS:
>
Description
23206
The FB is used to configure and control a digital or analogue output channel.
>
Input parameters
23162
Parameter
Data type
Description
Possible values
xResetError
BOOL
Reset request for an occurring error
FALSE
When switching from FALSE
TRUE: Reset request to the
lower level system
TRUE
uiChannel
UINT
Output channel
Group + channel
→ Data sheet
→
Note on wiring
(
→ p.
Examples:
703
Group 7 + channel 3
1203
Group 12 + channel 3
eMode
MODE_OUTPUT Operating type of the output channel
→
MODE_OUTPUT (ENUM)
(
→ p.
eFilter
FILTER_
OUTPUT
Filter definition of the output channel
→
FILTER_OUTPUT (ENUM)
(
→ p.
uiValue
UINT
Value that is to be written to the output
In the digital mode or sensor supply
mode; if setting at the eMode input =
OUT_DIGITAL_CSI
OUT_DIGITAL_CSO
OUT_SENSOR_05
OUT_SENSOR_10
FALSE Output deactivated
TRUE
Output activated
In analogue mode; if setting at the
eMode input =
OUT_ANALOGUE_10
Values indicated in [mV]
0...10 000