149
ifm
Programming Manual ecomatController/60-1 (CR711S) Operating System V2.5.0.n
2017-12-19
ifm function libraries
Library ifmOutHBridge
>
Output parameters
23472
Parameter
Data type
Description
Possible values
xError
BOOL
Indication if an error occurred during the FB
execution
FALSE
No error occurred or the FB is
still being executed
TRUE
Error occurred
Action could not be
executed
Note diagnostic
information
eDiagInfo
DIAG_INFO Diagnostic information
→ List below (diagnostic codes:)
xPrepared
BOOL
State of the FB outputs
FALSE
FB outputs still invalid; FB is
still processed
TRUE
FB outputs valid; FB has been
processed
uiOutCurrent
UINT
Measured current at the PWM output during
normal operation in [mA]
When braking, uiOutCurrent is = 0 because
no regular current exists in the lowside path.
available = 0...final value of the
measuring range
>