Programming Manual ecomatController/60-1 (CR711S) Operating System V2.5.0.n
2017-12-19
ifm function libraries
Library ifmRawCAN.library
>
Output parameter
7135
Parameter
Data type
Description
Possible values
xError
BOOL
Indication if an error occurred during the FB
execution
FALSE
No error occurred or the FB is
still being executed
TRUE
Error occurred
Action could not be
executed
Note diagnostic
information
eDiagInfo
DIAG_INFO Diagnostic information
→ List below (diagnostic codes:)
Diagnostic codes:
STAT_INACTIVE
State: FB/Function is inactive.
STAT_DONE
State: FB/Function has been successfully executed and completed. There are valid
results on the outputs.
ERR_BUS_OFF
Error: CAN interface is in the "BUS OFF" state
ERR_INTERNAL
Error: Internal system error
► Contact the ifm Service Center!
ERR_INVALID_VALUE
Error: at least 1 invalid input parameter or invalid combination of input parameters;
Function call has been stopped.
ERR_BAUDRATE_ALREADY_
SET
Error: Requested baud rate cannot be set because another baud rate has already been
defined.
ERR_UNDEFINED
Error: Unknown error
► Contact the ifm Service Center!
>