145
ifm
Programming Manual ecomatController/60-1 (CR711S) Operating System V2.5.0.n
2017-12-19
ifm function libraries
Library ifmOutGroup
>
Diagnostic codes (
→
Messages / diagnostic codes of the function blocks
(
ERR_INVALID_VALUE
Error: At least one input parameter is invalid or outside the value range.
ERR_INTERNAL
Error: Internal system error
► Contact the ifm Service Center!
ERR_UNDEFINED
Error: Unknown error
► Contact the ifm Service Center!
ERR_STUCK_AT_HIGH
Error: Signal frozen, signal state high.
ERR_STUCK_AT_LOW
Error: Signal frozen, signal state low.
ERR_UNDERVOLTAGE_VBBX
For inputs: Error: Reference voltage not reached.
For outputs. Error: The voltage of the corresponding output group supply or at
VBB30 / VBB15 is not reached.
ERR_OVERVOLTAGE_VBBX
For inputs: Error: Reference voltage exceeded.
For outputs. Error: Voltage of the corresponding output groups supply or at VBB30
/ VBB15 not reached.
DIAG_INVALID_VALUE
At least one input parameter is invalid or exceeds the permissible area.
DIAG_INTERNAL
Internal system error.
DIAG_ACCESS
FB/Function cannot access the required resource; Resource is blocked by another task.
DIAG_UNDERVOLTAGE_VBBX
For inputs: Error: Reference voltage not reached.
For outputs. Error: The voltage of the corresponding output group supply or at
VBB30 / VBB15 is not reached.
DIAG_OVERVOLTAGE_VBBX
For inputs: Error: Reference voltage exceeded.
For outputs. Error: Voltage of the corresponding output groups supply or at VBB30
/ VBB15 not reached.
DIAG_STUCK_AT_HIGH
Error: Signal frozen, signal state high.
DIAG_STUCK_AT_LOW
Error: Signal frozen, signal state low.
DIAG_NO_CALIB
The selected resource has no valid calibration.
The displayed values are maybe faulty.
DIAG_OVERLOAD_CURRENT
Maximum current exceeded.
ERR_OVERLOAD_CURRENT
Error: Maximum current exceeded.
DIAG_AT_GROUP_OUTPUT
At least one output of the output group is in an error state.
ERR_AT_GROUP_OUTPUT
Error: At least one output of the output group is in an error state.
>