Appendix B. Error Codes
B-3
002C
LDI I/F error.
ACK IU event timeout
detected.
-
Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
before resuming normal library operations.
• If the problem persists, see “Contacting IBM
Technical Support” on page 7-1.
002D
LDI I/F error.
Response IU event timeout
detected.
-
002E
LDI I/F error.
Transfer Ready IU event
timeout detected.
-
002F
LDI I/F error.
Undefined error detected.
-
0040
A drive media error detected
upon insertion.
CHK 0040
1.
Verify that the cartridge is compatible with the
drive in your library. See “Media” on page 1-8.
2.
Verify that the cartridge is not write-protected.
See “Write-Protect Switch” on page 5-7.
3.
If it is a cleaning cartridge, verify that the
cartridge has not expired. See “Viewing the
Library Map” on page 4-16.
4.
Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
before resuming normal library operations.
• If the problem persists, see “Contacting IBM
Technical Support” on page 7-1.
0042
A drive load timeout error
detected upon insertion.
CHK 0042
Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
before resuming normal library operations.
• If the problem persists, see “Contacting IBM
Technical Support” on page 7-1.
0053
Response acknowledge error
received from bar code
reader. Suspect the bar code
reader cable connection.
CHK 0053
1.
Initiate an inventory. See “Conducting a Library
Inventory” on page 4-6 (Operator Panel) or
“Conducting a Library Inventory” on page 4-19
(Web User Interface).
2.
Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
before resuming normal library operations.
• If the problem persists, see “Contacting IBM
Technical Support” on page 7-1.
0056
Receive data checksum error
received from bar code
reader. Suspect the bar code
reader cable connection.
CHK 0056
0057
Invalid data received from
bar code reader. Suspect the
bar code reader cable
connection.
CHK 0057
0058
A bar code reader read-error
detected. Suspect the bar
code reader cable connection.
CHK 0058
0059
A bar code reader FLASH
control error detected.
Suspect the bar code reader
cable connection.
CHK 0059
005A
A bar code reader
diagnostics error detected.
Suspect the bar code reader
cable connection.
CHK 005A
Table B-1. Library error codes (continued)
Code (H)
Description
Panel Indication
Action Required
Summary of Contents for System Storage TS2900
Page 2: ......
Page 10: ...viii TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 14: ...xii TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 22: ...xx TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 24: ...xxii TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 36: ...1 12 TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 78: ...3 34 TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 114: ...4 36 TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 136: ...5 22 TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 192: ...A 22 TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 220: ...D 10 TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 230: ...F 4 TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 232: ...G 2 TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 238: ...H 6 TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 255: ......
Page 256: ...Part Number 45E3877 Printed in USA GC27 2212 00 1P P N 45E3877...