B-6
TS2900 Tape Autoloader Setup, Operator, and Service Guide
008A
X calibration error #3.
During X-drive calibration,
centering sensor OFF
condition could not be
detected. Suspect the
centering sensor, X motor, or
P motor.
CHK 008A
Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
before resuming normal library operations.
• If the problem persists, see “Contacting IBM
Technical Support” on page 7-1.
008B
X calibration error #4.
During X-drive calibration,
centering sensor ON
condition could not be
detected. Suspect the
centering sensor, X motor, or
P motor.
CHK 008B
008F
During X operation, the
cartridge magazine was
removed. Suspect the
magazine set sensor.
CHK 008F
1.
Confirm the magazine is closed.
2.
Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
before resuming normal library operations.
• If the problem persists, see “Contacting IBM
Technical Support” on page 7-1.
00B0
Failed to detect media in the
Accessor at completion of
GET operation. Suspect the
centering sensor, X motor, or
P motor.
CHK 00B0
1.
Confirm the media is compatible.
2.
Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
before resuming normal library operations.
• If the problem persists, see “Contacting IBM
Technical Support” on page 7-1.
00B1
No media is contained in the
specified cell (Cell Empty).
Suspect the centering sensor,
X motor, or P motor.
CHK 00B1
Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
before resuming normal library operations.
• If the problem persists, see “Contacting IBM
Technical Support” on page 7-1.
00B2
Media detected in the
Accessor at completion of
centering check operation.
Suspect the centering sensor.
CHK 00B2
1.
If the cartridge remains in the Accessor, try to
move the cartridge from the Accessor to the I/O
Station using the Operator Panel or Web User
Interface. Remove the cartridge from the library
and inspect for damage and replace, if
necessary.
2.
Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
before resuming normal library operations.
• If the problem persists, see “Contacting IBM
Technical Support” on page 7-1.
00B3
Media detected in the
Accessor at completion of
PUT operation. Suspect the
centering sensor.
CHK 00B3
00B8
Accessor error #1.
Reverse REV position (PP1)
error (Accessor origin not
detected or FWD position
detected). Suspect the P
origin sensor, FWD sensor, or
P motor.
CHK 00B8
Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
before resuming normal library operations.
• If the problem persists, see “Contacting IBM
Technical Support” on page 7-1.
Table B-1. Library error codes (continued)
Code (H)
Description
Panel Indication
Action Required
Summary of Contents for System Storage TS2900
Page 2: ......
Page 10: ...viii TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 14: ...xii TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 22: ...xx TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 24: ...xxii TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 36: ...1 12 TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 78: ...3 34 TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 114: ...4 36 TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 136: ...5 22 TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 192: ...A 22 TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 220: ...D 10 TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 230: ...F 4 TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 232: ...G 2 TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 238: ...H 6 TS2900 Tape Autoloader Setup Operator and Service Guide...
Page 255: ......
Page 256: ...Part Number 45E3877 Printed in USA GC27 2212 00 1P P N 45E3877...